Shanghai AI Lab Releases Sage-Med-Preview Medical MLLM

November 28, 2026

Shanghai AI Lab Releases Sage-Med-Preview Medical MLLM

At a Glance

Item Value
Repository internlm/Sage-Med-Preview
Family guide Intern-S2 guide (2 articles)
Published 2026-11-27
Formats safetensors
Paper arXiv:2611.34575
Source type Primary source (the publisher itself)

Values determined by this site’s code when the information was collected. Dates are JST.

What we checked ourselves

  • It needs about 21% fewer tokens than the Qwen3 tokenizer for the same Japanese text, so about 1.26× as much Japanese fits in the same context length, and generation is faster per character.

Details and conditions are in “Our Own Measurements” below.

Overview

Shanghai Artificial Intelligence Laboratory has released the medical multimodal model “Sage-Med-Preview" on Hugging Face. Based on Intern-S2-Preview, it is a MoE model with a total of 35B parameters and 3B active parameters. It handles medical knowledge, medical image reading, report generation, and visual grounding (identifying corresponding regions in images) within a single model.

According to the abstract of the paper, existing medical-specialized MLLMs fall short of general-purpose state-of-the-art MLLMs across many medical tasks, and merely increasing model size mainly boosts text capabilities while visual recognition remains difficult to improve. This model was created to investigate how medical multimodal capabilities actually scale. It was trained by screening 322.7M candidate records step by step, sequentially applying medical pre-training, staged SFT, and adaptive reinforcement learning.

Specifications

  • Total parameters: 35B (Active parameters: 3B)
  • Architecture: Mixture-of-Experts (InternS2PreviewForConditionalGeneration)
  • Base model: internlm/Intern-S2-Preview
  • Input/Output: Image + text → text (image-text-to-text)
  • Training data: Approximately 164M records and 226B tokens in total after filtering
  • Training procedure: Continued pre-training → task-oriented mid-training → 3-stage SFT → difficulty-adaptive reinforcement learning (using task-specific rewards and reference replay)
  • Context length during validation: 32,768 tokens (according to the model card’s vLLM configuration example)

Performance

According to the model card, the average score across 31 public medical multimodal benchmarks is 58.26. The averages for comparison targets are reported as 50.99 for the open medical model Hulu-Med-235B-A22B, 52.24 for the base model Intern-S2-Preview, 52.78 for GPT-5.4, and 49.18 for Claude-Opus-4.6. All scores are based on measurements by the publishers and use a 0 to 100 scale. Higher values indicate better performance for all metrics. The table reproduces the comparison table from the model card without altering the values.

→ Scroll horizontally to see all columns

Benchmark Metric Sage-Med 35B-A3B GPT-6.2 Sol GPT-5.4 Claude-Opus 4.6 Gemini-2.5 Flash Hulu-Med 235B-A22B
Multimodal understanding
OmniMedVQA Accuracy 95.54 82.56 75.90 78.02 71.33 86.46
GMAI-MMBench · val Accuracy 70.07 74.48 59.65 55.60 59.05 62.31
GMAI-MMBench · test Accuracy 71.26 75.26 60.68 56.51 60.63 62.60
VQA-RAD Accuracy 76.50 79.60 74.06 70.07 67.41 85.59
SLAKE Accuracy 88.11 82.00 80.37 75.36 72.49 85.39
MedFrameQA Accuracy 65.52 62.78 55.63 58.37 50.19 60.54
Specialized visual understanding
MMOral-OPG-Bench Accuracy 46.87 55.57 43.78 42.38 36.58 39.66
Fundus-MMBench Accuracy 62.74 61.94 45.48 45.16 40.48 57.90
ChestAgentBench Accuracy 83.72 84.92 73.44 78.60 62.08 82.56
MIMIC-EchoQA Accuracy 51.77 53.86 47.75 29.42 28.78 42.77
TemMed-Bench Accuracy 46.55 40.01 35.83 24.96 31.77 36.22
SMC-LUD Accuracy 99.81 72.59 61.85 48.89 54.81 53.70
Knowledge, reasoning & reliability
MMMU Pro-Med · 4-option Accuracy 74.48 87.76 68.18 72.73 72.03 56.64
MMLU-Pro-Med Accuracy 80.07 84.35 79.71 84.11 78.00 73.72
SuperGPQA-Med Accuracy 59.35 72.30 56.19 67.51 54.30 49.95
ClinHallu Accuracy 77.48 86.29 75.90 76.20 71.63 61.75
Report generation
MIMIC-CXR ROUGE-L 33.37 30.31 26.35 18.74 23.51 29.56
CheXpert Plus RaTEScore 53.20 50.82 50.79 47.10 45.47 49.15
Lung-Cancer CT † RaTEScore 66.52 58.80 64.32 58.56 67.17 66.13
Intraoral † ROUGE-L 28.59 25.20 14.67 16.06 16.86 25.49
Visual grounding
MedSG-Bench mIoU 31.73 58.83 0.23 0.46 17.65 0.07
Pneumonia † mIoU 44.18 44.19 26.78 33.86 19.11 3.06
Surgical attention † ACC@0.3 78.85 42.25 58.90 52.70 43.25 5.20
Surgical attention † mIoU 48.50 28.34 35.06 31.85 28.68 4.54
Held-out clinical understanding
Melanoma metastasis † Accuracy 76.80 75.26 59.79 71.91 19.33 64.43
Fundus classification † Accuracy 70.70 75.09 57.14 55.68 40.66 74.36
NPC · patient-level † Accuracy 49.18 43.44 27.87 27.87 28.69 27.87
NPC · slice-level † Accuracy 62.70 57.79 44.59 19.02 28.28 51.97
Ear disease † Accuracy 41.40 23.00 18.25 15.35 22.30 27.95
Intracranial tumor † Accuracy 40.00 50.00 37.14 34.29 25.71 30.00

† denotes unpublished benchmarks separated from the training data at both the institution and case levels. ACC@0.3 represents localization accuracy when the IoU exceeds 0.3. PET/CT items are excluded from this table due to overlap with the training data.

This table highlights its strength in medical tasks involving images. It records the highest values in OmniMedVQA, SLAKE, and MedFrameQA, and ranks first in 3 out of 4 report generation items. It outperforms the rest by a wide margin in SMC-LUD and Surgical attention.

On the other hand, in the “Knowledge, reasoning & reliability" category, it falls short of GPT-6.2-Sol across all items. The gaps are not small, with MMMU Pro-Med at 74.48 versus 87.76 and SuperGPQA-Med at 59.35 versus 72.30. Visual grounding’s MedSG-Bench also shows a large gap at 31.73 versus 58.83. However, Pneumonia is nearly tied at 44.18 versus 44.19.

Compared to the open-weight Hulu-Med-235B-A22B, it outperforms it in most items despite having a smaller active parameter count of 3B. It trails in only two items: VQA-RAD and Fundus classification. The paper’s abstract also acknowledges that significant challenges remain in complex medical reasoning and multi-stage clinical workflows.

Strengths and Use Cases

The model card lists the following four use cases for medical AI research and development:

  • Medical question answering
  • Medical image reading
  • Drafting radiology reports
  • Visual grounding (identifying corresponding regions in images)

It is also tagged with medical-vqa, report-generation, visual-grounding, and multimodal, indicating its specialization in medical tasks combining images and text.

Based on the first half of the table, medical image VQA and report generation are its most suited applications. Examples include having it explain findings from chest X-rays or draft reports. The client example in the model card also asks a chest radiograph to “Describe the visible findings in this chest radiograph." Conversely, for use cases asking for medical knowledge or reasoning without images, expectations should be kept modest as it falls behind comparative proprietary models in many items.

As a usage precaution, the model card positions this model as “designed to assist researchers and medical professionals." It explicitly states that clinical deployment requires confirmation and validation by experts in the actual deployment environment. Automated diagnosis is not an intended use case.

The base model Intern-S2-Preview is a 35B multimodal foundational model trained primarily on scientific tasks. It enables the thinking mode by default and supports tool calling. However, both the vLLM configuration example and request example in the model card set enable_thinking to false. The behavior of Sage-Med-Preview when using the thinking mode is not clear from the documentation. Supported languages are also not specified in the model card.

How to Get It

It is distributed in safetensors format from the Hugging Face repository internlm/Sage-Med-Preview. Downloading does not require agreeing to a license.

The model card provides instructions for using vLLM as the inference engine. The validation environment is as follows:

  • GPU: 1x NVIDIA H200
  • Precision: BF16
  • Context length: 32,768 tokens
  • Host: x86-64 Linux
  • Driver: NVIDIA driver supporting CUDA 12.9

The following commands are provided to prepare the environment:

pip install uv
uv venv --python 3.12 ~/.venvs/sage-med-vllm
source ~/.venvs/sage-med-vllm/bin/activate
curl -fsSL https://huggingface.co/internlm/Sage-Med-Preview/resolve/main/requirements-h200.txt -o requirements-h200.txt
uv pip install --torch-backend=cu129 -r requirements-h200.txt
vllm download-kernels

The server is launched with the following command. Model files are automatically downloaded from Hugging Face upon initial startup. If you have a downloaded copy locally, specify the directory containing config.json and weight files in MODEL_PATH. --trust-remote-code is required because it includes custom code.

MODEL_PATH="${MODEL_PATH:-internlm/Sage-Med-Preview}"
PORT="${PORT:-8000}"
export VLLM_USE_FLASHINFER_SAMPLER=0

vllm serve "$MODEL_PATH" \
    --host 127.0.0.1 \
    --port "$PORT" \
    --trust-remote-code \
    --served-model-name sage-med-preview \
    --dtype bfloat16 \
    --tensor-parallel-size 1 \
    --gpu-memory-utilization 0.85 \
    --max-model-len 32768 \
    --max-num-seqs 8 \
    --max-num-batched-tokens 4096 \
    --limit-mm-per-prompt '{"image":1,"video":0}' \
    --generation-config vllm \
    --no-enable-prefix-caching \
    --enforce-eager \
    --default-chat-template-kwargs '{"enable_thinking":false}'

After startup, inference is performed by sending images and text to the OpenAI-compatible /v1/chat/completions. The model card’s request example sets temperature to 0.01. In this configuration example, up to one image can be passed per request, and videos are not accepted.

While the base model Intern-S2-Preview provides guidance for operation on LMDeploy, vLLM, and SGLang, the Sage-Med-Preview model card only includes instructions for vLLM. The documentation does not mention quantized versions such as GGUF, or compatibility with llama.cpp and Ollama.

Can You Run It Locally?

Not usable in Ollama, LM Studio and llama.cpp yet.

The publisher ships safetensors only, and llama.cpp’s registry does not list this architecture. llama.cpp would need to add support before these tools can run it. Today it can be run with transformers or vLLM, using the memory figures in the table above.

Compiled by this site’s code from the published formats, converted builds we have found, and each engine’s own model registry. “Not found" means we have not seen such a build, not that none exists.

Our Own Measurements

Values we checked ourselves on our server (no GPU) by actually reading this model’s files, without running the model — not figures copied from the model card. How we measure, and the results for every model: Our Measurements.

Measurements We Did Not Take

This model does not state a license, so we cannot confirm permission to use it. Because this site carries advertising, we did not run the model (no CPU run, answers, quantization comparison, conversion or generation). Only values we checked without running the model, such as token counts and the GGUF header, are shown.

Japanese Token Efficiency

Tokenizer Tokens per 1,000 Japanese characters Ratio to the same text in English
This model 546 0.99×
Qwen3 688 1.26×
Llama 3.2 744 1.36×
Gemma 3 564 1.03×
gpt-oss 795 1.45×
LLM-jp-3 497 0.85×

It needs about 21% fewer tokens than the Qwen3 tokenizer for the same Japanese text, so about 1.26× as much Japanese fits in the same context length, and generation is faster per character.

Counted with the tokenizer.json of internlm/Intern-S2-Preview on a fixed text we wrote ourselves (876 Japanese characters across news, conversation, technical docs, a formal email, travel writing and a recipe) and its English translation. Fewer tokens mean more Japanese fits in the context window.

Related Articles

What to Read Next

Sources

Update History

  • 2026-11-28: Added our own measurements: Japanese token efficiency.